10/1/09 Price List (800) 754–5165
88
Fixed Systems Controllers
Beacon 800 Eight Channel Wall Mount Controller
ORDERING INFORMATION: When ordering a Beacon 800 system please specify the following compo-
nents:
1) Controller
2) Detector Assemblies (up to 8)
3) Any options desired such as heavy duty relay board or individual recorder output board.
Note
All sensors connected to the Beacon 800 must use a 4-20 mA transmitter.
Part# Description Suggested Retail
72-2108RK Beacon 800, eight channel controller (no sensors) ……………………………………………………… 2,195.00
Controller
Options
(These items are factory installed and must be ordered with the instrument)
75-0004RK Recorder output board, 8 outputs, 4-20 mA or 1-5 VDC, added to Beacon 800 …………………………… 280.00
75-0005RK Heavy duty relay board, 4 relays at 30 amps, added to Beacon 800 ……………………………………… 200.00
75-0006RK Relay board and recorder output board, added to Beacon 800 …………………………………………… 480.00
Detector assemblies
Refer to detector assembly sections for complete listing
Refer to Legacy Products section for the following detector assemblies
S2 Series Sensor / transmitter with explosion proof and non explosion proof junction box (no display) ……… page 91
S2 Toxic Series Sensor / transmitter for toxics (ESM-01 sensors), non explosion proof, with junction box (no display) … page 95
M2 Series Stand alone sensor / transmitter with explosion proof junction box and digital display ……………… page 92
M2 Toxic Series Stand alone sensor / transmitter for toxics (ESM-01 sensors) with junction box and digital display …… page 95
M-Series Low cost sensor / transmitter (non explosion proof) …………………………………………………… page 100
35-3000 Sample draw detector assembly in NEMA 4X enclosure ………………………………………………… page 101
35-3010 Sample draw, multi-sensor detector assembly in NEMA 4X enclosure ………………………………… page 101
GD-70D Electrochemical sample draw detector assembly with digital display for toxic gases ………………… page 97
GD-K8A Electrochemical diusion detector assembly for toxic gases …………………………………………… page 98
S-Series Sensor / transmitter with explosion proof junction box (no display) …………………………………… page 105
GD-K7D2 Electrochemical sample draw detector assembly for toxic gases ……………………………………… page 108
GD-K71D Electrochemical sample draw detector assembly with digital display for toxic gases ………………… page 107
Notes
• Fixed system pricing is for equipment only and does not include factory start-up or training. Please contact RKI for quotation
if factory start-up or training is needed.
• Please contact RKI if you would like assistance with pricing or conguring a system quotation.
• A calibration test kit is a strongly recommended accessory for all xed systems.
• Legacy products are still available.
Replacement Parts & Accessories
For a complete listing of replacement parts and accessories see page 110.