31 M2 Rig Monitor Operator’s Manual
Adjusting Strobe/Horn Volume
The horn volume on the strobe/horn can be adjusted by doing the following:
1. Disconnect the battery clamps from the + and - terminals of the 12 VDC battery.
2. Loosen the captive screw at the bottom front of the strobe/horn.
3. Grasp the top and bottom of the strobe/horn and push up and out in order to remove
the cover.
Figure 10: Top Case Removal
4. Turn the cover over and locate the Audio Select switch at the top of the cover as
shown in the figure below.
Figure 11: Strobe/Horn Cover
5. The Audio Select switch can be set at any number between 1 and 6. Numbers 1-3 all
produce an intermittent buzzing sound with 1 being the loudest and 3 being the
quietest. Numbers 4-6 all produce a steady buzzing sound with 4 being the loudest
and 6 being the quietest. The factory setting is 2.
Push Up Here
Captive
Screw
Push Out
Top
Base
Audio Select Switch
AUDIO
SELECT
6
Strobe Brightness Switch
(DO NOT ADJUST)
1
2
3
4
5
CANDELLA SELECT